The Indicator Setting configures communication between the weighing indicator and the Weighbridge Software.

How it works

Open Master → Indicator Setting and configure: • Baud Rate • String Length • Start Index • Number of Digits • String Value Save the parameters, then select the configured indicator from Software Settings → General Settings → Indicator. Once configured, the software receives the live weight automatically.